Negative pressure intubation box integrates a virus containing enclosure made of acrylic connected to a virus filtration unit and negative suction. During intubation for ventilating the critical care COVID patients large quantities of virus-containing aerosols are released into the operation theatre since the breathing air path is wide open for intubation. Other aerosol-generating procedures are extubation, tracheostomy, oropharyngeal/tracheal aspiration, bronchoscopy, esophagogastroduodenoscopy, transesophageal echocardiography, defibrillation, chest compression, and a range of head, neck, and thoracic surgeries.

Design

Made in India

A thoughtful design meant to work efficiently without compromising the functions. The shape of the product directly represents the purity of the product and its main function. A user oriented design provides an amazing balance between the aesthetics and function in the best way.

Specifications

Best in class features

  • ACH (air changes per hour) :17
  • Filtration : H13 Hepa filter (99.97% @ 0.3 micron) of 75 mm depth and 1ft x1ft size, 10 micron pre filter of 50mm depth and 1ft x1ft size, hepa filter area 1300cm2.
  • UV light 250-270nm,1500 microWatt/cm2.
  • Weight : 9Kg.
  • Motor: Brushless DC motor.
  • Power supply : 230v or 12v DC.
  • Product size : 30cmx30cmx36cm(suction box)
  •  Filter replacement time is 2 years for HEPA filter and 6 months for Pre-filter.
Purifying done really quick
0 min
Long lasting HEPA Filter
0 Years

Purification

Why do operation theatres with COVID patients need Negative pressure Intubation box?

A typical operation theatre has two problems when it comes to COVID patients. One it’s built on positive pressure air cleaning technology which leaks contaminated air from inside the operation theatre to outside the hospital environment. Second HEPA filter based room air cleaning system with typical air changes of 15 per hour, is awfully inadequate to contain the locally emitted virus aerosol before infecting the hospital staff. 

Viral concentration in a 300 sqft room with 600 CFM HEPA system with ACH(air changes per hour) 15 will take 16 minutes to fall below 99%, whereas Negative pressure Intubation box with ACH(air changes per hour) 900 will take 1 minute to remove 99% virus. Negative pressure Intubation box will also work equally well in COVID wards without an air cleaning system since it is a portable system.

0 %
Intubation Box

Carry easy

Ergonomic design

An elegant handle design provides the best ergonomic solution to move the product around comfortably. Made from the strongest Stainless steel, the handle will be strong and durable for a long term use. The grips provided in the handle gives a comfortable and strong hold to carry it around with ease.